top of page
888-428-1161
713-699-0074
No After Hours Additional Fees!
"Service Is Our First Priority"
General Electric
120/240V Residential/Commercial
Type THQL - stab-in / plug-in
Voltage range - 120/208/240V
Single pole - 15-70A
Two pole - 15-125A
Three pole - 15-100A
Available with ground / arc fault, shunt trip
Type THQB - bolt-in
Voltage range - 120/208/240V
Single pole - 15-70A
Two pole - 15-100A
Three pole - 15-100A
Available with ground / arc fault, shunt trip
Type THQP - SLIM stab-in / plug-in
Voltage range - 120/208/240V
Single pole - 15-50A
Two pole - 15-50A
No applicable accessories
Type THQC - feed-thru
Voltage range - 120/208/240V
Single pole - 15-70A
Two pole - 15-100A
Three pole - 20-100A
Single pole 15-30A available with ground fault
Type THQMV - load center main
Voltage range - 120/208/240V
Single phase - 100-225A
Used in PowerMark Gold load centers
Type TQD - meter module main
Voltage range - 120/208/240V
Single/three phase - 100-225A
Used in Tenant Meter Modules
and single breaker enclosures
480/600V Commercial/Industrial
Spectra Series - SE Frame
Maximum Voltage - 600V
Amperage Range - 15-150A
Available with shunt trip, auxiliary switch, alarm bell
Spectra Series - SF Frame
Maximum Voltage - 600V
Amperage Range - 70-250A
Available with shunt trip, auxiliary switch, alarm bell
Spectra Series - SG Frame
Maximum Voltage - 600V
Amperage Range - 150-600A
Available with shunt trip, auxiliary switch, alarm bell
Spectra Series - SK Frame
Maximum Voltage - 600V
Amperage Range - 400-1200A
Available with shunt trip, auxiliary switch, alarm bell
TED / THED
Maximum Voltage - 600V
Amperage Range - 15-150A
Single, two, and three pole
Available with shunt trip, auxiliary switch,
undervoltage release
TEY - bolt-in (classic style)
Maximum Voltage - 600V
Amperage Range - 15-100A
Single, two, and three pole
Available with factory installed shunt trip
TEY - bolt-in (new style)
Maximum Voltage - 600V
Amperage Range - 15-125A
Single, two, and three pole
No applicable accessories
TF Frame
Maximum Voltage - 600V
Amperage Range - 70-250A
Single/three phase
Available with shunt trip, auxiliary switch,
undervoltage release
TJ Frame
Maximum Voltage - 600V
Amperage Range - 125-400A
Single/three phase
Available with shunt trip, auxiliary switch,
undervoltage release
TK Frame
Maximum Voltage - 600V
Amperage Range - 300-800A
Single/three phase
Available with shunt trip, auxiliary switch,
undervoltage release
Record+ Series (obsolete)
Maximum Voltage - 600V
Amperage Range - 15-100A
Single, two, and three pole
No applicable accessories
Call Toll-Free
888-428-1161
Have an Emergency?
We are Available
24 Hours a Day
6 Days a Week
No Minimums
No Fees