Eaton
120/240V Residential/Commercial
Type BAB - bolt-in
Voltage range - 120/208/240V
Single pole - 15-70A
Two pole - 15-125A
Three pole - 15-100A
Available with ground / arc fault, shunt trip
Type BR - stab-in / plug-in
Voltage range - 120/208/240V
Single pole - 15-70A
Two pole - 15-150A
Three pole - 15-100A
Available with ground / arc fault, shunt trip
Type CHB - bolt-in (legacy)
Voltage range - 120/208/240V
Single pole - 15-70A
Two pole - 15-125A
Three pole - 15-100A
Available with ground / arc fault
Type CH - stab-in / plug-in
Voltage range - 120/208/240V
Single pole - 15-70A
Two pole - 15-225A
Three pole - 15-100A
Available with ground / arc fault, shunt trip
Type BD - stab-in / plug-in
Voltage range - 120/208/240V
Tandem - 15/15A-30/50A
No applicable accessories
Type BQ - stab-in / plug-in
Voltage range - 120/208/240V
Quad - 15-50A
No applicable accessories
Type QC - feed-thru
Voltage range - 120/208/240V
Single pole - 15-70A
Two pole - 15-100A
Three pole - 15-100A
No applicable accessories
Type BW (CSR) - bolt-in main breaker
Voltage range - 120/208/240V
Single phase - 125-225A
No applicable accessories
Type BJ - stab-in main breaker
Voltage range - 120/208/240V
Single phase - 100-225A
Three phase - 125-225A
No applicable accessories
480/600V Commercial/Industrial
Type GHB - bolt-in
Maximum voltage - 480V
Single pole - 15-70A
Two pole- 15-100A
Three pole - 15-100A
Available with factory installed shunt trip
ED / EHD
Maximum voltage - 600V
Single, two, and three pole - 15-100A
Available with shunt trip, auxiliary switch
FD / HFD
Maximum voltage - 600V
Single, two, and three pole - 15-225A
Available with shunt trip, auxiliary switch
HMCP - motor circuit protector
Maximum voltage - 600V
Three phase - 3-600A
Available with shunt trip, auxiliary switch
JD
Maximum voltage - 600V
Single/three phase - 100-250A
Available with shunt trip, auxiliary switch
KD
Maximum voltage - 600V
Single/three phase - 100-400A
Available with shunt trip, auxiliary switch
LD
Maximum voltage - 600V
Single/three phase - 300-600A
Available with shunt trip, auxiliary switch
MD
Maximum voltage - 600V
Single/three phase - 400-800A
Available with shunt trip, auxiliary switch
ND
Maximum voltage - 600V
Single/three phase - 800A and 1200A
Available with LSIG electronic trip functions
PB
Maximum voltage - 600V
Single/three phase - 1000-1200A
Available with shunt trip, auxiliary switch
CA / CC (obsolete)
Maximum voltage - 480V
Single/three phase - 100-225A
No applicable accessories